It is preferred to use typed property access functions (i.e.
of_property_read_<type> functions) rather than low-level
of_get_property/of_find_property functions for reading properties.
Convert reading boolean properties to to of_property_read_bool().
Signed-off-by: Rob Herring <robh@kernel.org>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
of_property_read_string(np, "cm-thermal-zone", &desc->thermal_zone);
of_property_read_u32(np, "cm-battery-cold", &desc->temp_min);
- if (of_get_property(np, "cm-battery-cold-in-minus", NULL))
+ if (of_property_read_bool(np, "cm-battery-cold-in-minus"))
desc->temp_min *= -1;
of_property_read_u32(np, "cm-battery-hot", &desc->temp_max);
of_property_read_u32(np, "cm-battery-temp-diff", &desc->temp_diff);