serial: imx: Fix the RTS GPIO polarity in RS485 mode
On a board that needs to drive RTS GPIO high in order to enable the
transmission of a RS485 transceiver the following description is
passed in the devide tree:
/* set logical level for RTS pin equal to 1 when sending: */
rs485conf.flags |= SER_RS485_RTS_ON_SEND;
/* set logical level for RTS pin equal to 0 after sending: */
rs485conf.flags &= ~(SER_RS485_RTS_AFTER_SEND);
However the RTS GPIO polarity observed in the oscilloscope is inverted.
When the SER_RS485_RTS_ON_SEND flag is set the imx_port_rts_active()
function should be called and following the same logic when
SER_RS485_RTS_AFTER_SEND flag is cleared the imx_port_rts_inactive()
should be called.
Do such logic change so that RS485 communication in half duplex can
work successfully when the RTS GPIO pin is passed via device tree.