From fdabacecf0af242d92e312faa4df6c24857f8935 Mon Sep 17 00:00:00 2001
From: Patrick Delaunay <patrick.delaunay@st.com>
Date: Wed, 12 Feb 2020 19:37:36 +0100
Subject: [PATCH] board: stm32mp1: read OTP in command stboard

Read the value directly from the OTP and no more of the shadows
to avoid the need of reboot after stboard command to have correct value.

Signed-off-by: Patrick Delaunay <patrick.delaunay@st.com>
Acked-by: Patrice Chotard <patrice.chotard@st.com>
---
 board/st/common/cmd_stboard.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/board/st/common/cmd_stboard.c b/board/st/common/cmd_stboard.c
index b740f4510e..c7ca773b1c 100644
--- a/board/st/common/cmd_stboard.c
+++ b/board/st/common/cmd_stboard.c
@@ -58,7 +58,7 @@ static int do_stboard(cmd_tbl_t *cmdtp, int flag, int argc,
 					  DM_GET_DRIVER(stm32mp_bsec),
 					  &dev);
 
-	ret = misc_read(dev, STM32_BSEC_SHADOW(BSEC_OTP_BOARD),
+	ret = misc_read(dev, STM32_BSEC_OTP(BSEC_OTP_BOARD),
 			&otp, sizeof(otp));
 
 	if (ret < 0) {
-- 
2.39.5