From: Jan Kiszka Date: Tue, 22 Oct 2024 06:04:18 +0000 (+0200) Subject: board: siemens: iot2050: Fix mistake in list of writable env vars X-Git-Url: http://git.dujemihanovic.xyz/login.html?a=commitdiff_plain;h=23750f60fa1e30e69c4eab748582d8d078a01b72;p=u-boot.git board: siemens: iot2050: Fix mistake in list of writable env vars This prevented to set m2_manual_config - as evaluated by m2_connector_setup - under strict configurations for secure boot. Signed-off-by: Jan Kiszka Reviewed-by: Michael Trimarchi --- diff --git a/include/configs/iot2050.h b/include/configs/iot2050.h index 94a9c76788..0f92e0d25d 100644 --- a/include/configs/iot2050.h +++ b/include/configs/iot2050.h @@ -39,7 +39,7 @@ #define CFG_ENV_FLAGS_LIST_STATIC \ "board_uuid:sw,board_name:sw,board_serial:sw,board_a5e:sw," \ "mlfb:sw,fw_version:sw,seboot_version:sw," \ - "m2_manuel_config:sw," \ + "m2_manual_config:sw," \ "eth1addr:mw,eth2addr:mw,watchdog_timeout_ms:dw,boot_targets:sw" #endif