Commit
44645f87de5 ("mmc: Fix mmc_switch excessive timeout") introduced
a side effect where CMD13 SEND_STATUS is issued in case mmc_wait_dat0()
does not return -ENOSYS and $send_status is not set. This happens on all
hardware which does implement .mmc_wait_dat0 callback, e.g. i.MX8M .
This leads to lengthy timeout before booting OS in case of eMMC in one
of the HS200/HS400 modes, since the card cannot respond to CMD13 while
downgrading from HS200/HS400 to regular HS mode.
Fix this by adding the missing conditional.
Fixes: 44645f87de5 ("mmc: Fix mmc_switch excessive timeout")
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Jaehoon Chung <jh80.chung@samsung.com>
Cc: Kirill Kapranov <kirill.kapranov@compulab.co.il>
Cc: Marek BehĂșn <marek.behun@nic.cz>
Cc: Pantelis Antoniou <panto@antoniou-consulting.com>
Cc: Ye Li <ye.li@nxp.com>
Reviewed-by: Jaehoon Chung <jh80.chung@samsung.com>
return 0;
}
+ if (!send_status)
+ return 0;
+
/* Finally wait until the card is ready or indicates a failure
* to switch. It doesn't hurt to use CMD13 here even if send_status
* is false, because by now (after 'timeout_ms' ms) the bus should be