spi: zynqmp_gqspi: fix set_speed bug on multiple runs
If zynqmp_qspi_set_speed() is called multiple times with the same speed,
then on the second call it will skip recalculating the baud_rate_val as
it assumes the speed is already configured correctly. But it will still
write the baud_rate_val to the configuration register and call
zynqmp_gqspi_set_tapdelay(). Because it skipped recalculating the
baud_rate_val, it will use the initial value of 0 . This causes the
driver to run at maximum speed which for many spi flashes is too fast and
causes data corruption.
Instead only write out a new baud_rate_val if we have calculated the
correct baud_rate_val.
This opens up another issue with the "if (speed == 0)", we don't save
off the new plat->speed_hz value when setting the baud rate on the
speed=0 path. Instead mimic what the Linux zynqmp gqspi driver does, and
have speed==0 just use the same calculation as a normal speed. That will
cause the baud_rate_val to use the slowest speed possible, which is the
safest option.