From: Fabio Estevam Date: Mon, 4 Jan 2016 23:38:08 +0000 (-0200) Subject: mx6cuboxi: Fix the reset delay for the AR8035 PHY X-Git-Url: http://git.dujemihanovic.xyz/img/sics.gif?a=commitdiff_plain;h=4b421d4ea179f8aed52c5b1be45c4dd75a529c91;p=u-boot.git mx6cuboxi: Fix the reset delay for the AR8035 PHY Since commit 59370f3fcd1350 ("net: phy: delay only if reset handler is registered") Ethernet is no longer functional: Booting from net ... FEC Waiting for PHY auto negotiation to complete......... TIMEOUT ! BOOTP broadcast 1 BOOTP broadcast 2 BOOTP broadcast 3 BOOTP broadcast 4 This commit does not have an issue in itself, but it revelead a problem with the Ethernet initialization. As per the AR8035 datasheet: "For a reliable power on reset, suggest to keep asserting the reset low long enough (10ms) to ensure the clock is stable and clock-to-reset 1ms requirement is satisfied." So do as suggested and keep the reset low for 10ms. Also add a 100us delay after deasserting the reset line to guarantee that the PHY ID can be read correctly and the Atheros PHY can be loaded as per Troy Kisky's suggestion. Signed-off-by: Fabio Estevam Tested-by: Tom Rini --- diff --git a/board/solidrun/mx6cuboxi/mx6cuboxi.c b/board/solidrun/mx6cuboxi/mx6cuboxi.c index fc37f1eef0..18b08d12fa 100644 --- a/board/solidrun/mx6cuboxi/mx6cuboxi.c +++ b/board/solidrun/mx6cuboxi/mx6cuboxi.c @@ -143,8 +143,9 @@ static void setup_iomux_enet(void) SETUP_IOMUX_PADS(enet_pads); gpio_direction_output(ETH_PHY_RESET, 0); - mdelay(2); + mdelay(10); gpio_set_value(ETH_PHY_RESET, 1); + udelay(100); } int board_phy_config(struct phy_device *phydev)