The generic timer count is an incrementing 64bit value and a timer driver
must return an incrementing 64bit value. The DW APB timer only provides a
32bit timer counting down, thus the result must be inverted and converted
to a 64bit value. The current implementation is however missing the 64bit
up-conversion and this results in random timer roll-overs, which in turn
triggers random timeouts throughout the codebase.
This patch adds the missing 64bit up-conversion to fix the issue.
Signed-off-by: Marek Vasut <marex@denx.de>
Cc: Chin Liang See <chin.liang.see@intel.com>
Cc: Dinh Nguyen <dinguyen@kernel.org>
Cc: Ley Foon Tan <ley.foon.tan@intel.com>
Cc: Simon Goldschmidt <simon.k.r.goldschmidt@gmail.com>
Cc: Tien Fong Chee <tien.fong.chee@intel.com>
* requires the count to be incrementing. Invert the
* result.
*/
- *count = ~readl(priv->regs + DW_APB_CURR_VAL);
+ *count = timer_conv_64(~readl(priv->regs + DW_APB_CURR_VAL));
return 0;
}