Add bindings for CPU. This will allow displaying correctly the crystal,
CPU and master clock.
Reported-by: Eugen Hristev <eugen.hristev@microchip.com>
Fixes: a64862284f65 ("clk: at91: sam9x60: add support compatible with
CCF")
Signed-off-by: Claudiu Beznea <claudiu.beznea@microchip.com>
};
};
+ cpus {
+ #address-cells = <1>;
+ #size-cells = <0>;
+
+ ARM9260_0: cpu@0 {
+ device_type = "cpu";
+ compatible = "arm,arm926ej-s";
+ clocks = <&pmc PMC_TYPE_CORE 19>, <&pmc PMC_TYPE_CORE 11>, <&main_xtal>;
+ clock-names = "cpu", "master", "xtal";
+ };
+ };
+
ahb {
compatible = "simple-bus";
#address-cells = <1>;