H616 uses different address for reset. Add it.
Signed-off-by: Jernej Skrabec <jernej.skrabec@siol.net>
Reviewed-by: Andre Przywara <andre.przywara@arm.com>
Signed-off-by: Andre Przywara <andre.przywara@arm.com>
str w2, [x1]
ldr x0, =0xfa50392f // CPU hotplug magic
-#ifdef CONFIG_MACH_SUN50I_H6
+#ifdef CONFIG_MACH_SUN50I_H616
+ ldr x2, =(SUNXI_R_CPUCFG_BASE + 0x1c0)
+ str w0, [x2], #0x4
+#elif CONFIG_MACH_SUN50I_H6
ldr x2, =(SUNXI_RTC_BASE + 0x1b8) // BOOT_CPU_HP_FLAG_REG
str w0, [x2], #0x4
#else