From 49f0b6bab919e6a9a509af841b43bbb49728dc45 Mon Sep 17 00:00:00 2001
From: Stefan Roese <sr@denx.de>
Date: Tue, 15 Jan 2019 13:54:26 +0100
Subject: [PATCH] mips: mt7688: gardena-smart-gateway: Enable green power LED
 on startup

Set the correct power-up state (default-state) of the green power LED.

Signed-off-by: Stefan Roese <sr@denx.de>
Cc: Daniel Schwierzeck <daniel.schwierzeck@gmail.com>
---
 arch/mips/dts/gardena-smart-gateway-mt7688.dts | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/mips/dts/gardena-smart-gateway-mt7688.dts b/arch/mips/dts/gardena-smart-gateway-mt7688.dts
index d8d88686bb..75f6037e96 100644
--- a/arch/mips/dts/gardena-smart-gateway-mt7688.dts
+++ b/arch/mips/dts/gardena-smart-gateway-mt7688.dts
@@ -34,7 +34,7 @@
 		power_green {
 			label = "smartgw:power:green";
 			gpios = <&gpio0 19 GPIO_ACTIVE_HIGH>;
-			default-state = "off";
+			default-state = "on";
 		};
 
 		power_red {
-- 
2.39.5