Allow to disable serial console in SPL. Weak dependency is already used
with TPL serial.
Signed-off-by: Daniel Semkowicz <dse@thaumatec.com>
Reviewed-by: Quentin Schulz <quentin.schulz@cherry.de>
Reviewed-by: Simon Glass <sjg@chromium.org>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
select SPL_SYSCON if SPL
select TPL_NEEDS_SEPARATE_STACK if TPL
select SPL_SEPARATE_BSS
- select SPL_SERIAL
select CLK
select FIT
select PINCTRL
imply SPL_DM_SEQ_ALIAS
imply SPL_FIT_SIGNATURE
imply SPL_ROCKCHIP_COMMON_BOARD
+ imply SPL_SERIAL
imply SYS_BOOTCOUNT_SINGLEWORD if BOOTCOUNT_LIMIT
imply TPL_CLK
imply TPL_DM