clk: rockchip: rk3568: Fix reset handler
The reset handler for rk3568 is missing its private data. This leads to
an abort when a reset is triggered.
=> reset
resetting ...
"Synchronous Abort" handler, esr 0x96000045
elr:
0000000000a2bc04 lr :
0000000000a2bbd4 (reloc)
elr:
00000000eff9bc04 lr :
00000000eff9bbd4
x0 :
00000000fdd20000 x1 :
0000000014000001
x2 :
000000000000fdb9 x3 :
00000000edf77e88
x4 :
00000000edf50e78 x5 :
00000000edf77530
x6 :
000000000000001d x7 :
00000000edf8a1d0
x8 :
00000000ffffffd8 x9 :
0000000000000008
x10:
000000000000000d x11:
0000000000000006
x12:
000000000001869f x13:
0000000086c290c5
x14:
000000009118e878 x15:
0000000000000000
x16:
00000000eff9bbb8 x17:
0000000012f8c119
x18:
00000000edf50dc0 x19:
0000000000000000
x20:
0000000000000001 x21:
0000000000000000
x22:
00000000edf85900 x23:
0000000000000001
x24:
00000000effe8bbc x25:
0000000000000000
x26:
00000000edf85940 x27:
0000000000000000
x28:
0000000000000000 x29:
00000000edf3c8e0
Code:
d65f03c0 d5033fbf b9400661 529d9502 (
b8216802)
Resetting CPU ...
Add the missing dev_set_priv to the rk3568 clk driver to fix this.
Fixes: 4a262feba3a5 ("rockchip: rk3568: add clock driver")
Signed-off-by: Peter Geis <pgwipeout@gmail.com>
Reviewed-by: Kever Yang <kever.yang@rock-chips.com>
Reviewed-by: Jagan Teki <jagan@amarulasolutions.com>
Tested-by: Jagan Teki <jagan@amarulasolutions.com> # radxa-cm3
Signed-off-by: Jonas Karlman <jonas@kwiboo.se>